kyoritsu KEW 1009 Digital Multimeter - Variety House

kyoritsu KEW 1009 Digital Multimeter

• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.

69 / 100

kyoritsu KEW 1009 Digital Multimeter

• Display: 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns the power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.

Features

69 / 100

• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster

Specifications

69 / 100
DC V400mV/4/40/400/600V (Input Impedance 10MΩ) ±0.6%rdg±4dgt (400mV/4/40/400V) ±1.0%rdg±4dgt (600V)
AC V400mV/4/40/400/600V (Input Impedance 10MΩ) ±1.6%rdg±4dgt (20 – 400mV) ±1.3%rdg±4dgt (4/40V) ±1.6%rdg±4dgt (400/600V)
DC A400/4000µA/40/400mA/4/10A ±2.0%rdg±4dgt
(400/4000µA)±1.0%rdg±4dgt
(40/400mA) ±1.6%rdg±4dgt (4/10A)
AC A400/4000µA/40/400mA/4/10A ±2.6%rdg±4dgt
(400/4000µA) ±2.0%rdg±4dgt (40/400mA/4/10A)
Ω400Ω/4/40/400kΩ/4/40MΩ ±1.0%rdg±4dgt (400Ω/4/40/400kΩ/4MΩ) ±2.0%rdg±4dgt (40MΩ)
Continuity buzzer400Ω (Buzzer sounds below 100Ω)
Diode test1.5V Release Voltage:Approx. 0.4mA Test Current
Capacitance40/400nF/4/40/100µF
Frequency5.12/51.2/512Hz/5.12/51.2/512kHz/5.12/10MHz
DUTY0.1 – 99.9% (Pulse width/Pulse period) ±2.5%±5dgt
Applicable standardsIEC 61010-1 CAT III 300V
IEC 61010-2-031
IEC 61326
Power sourceR6 (1.5V) × 2
Dimensions161(L) × 82(W) × 50(D)mm
WeightApprox. 280g
Included Accessories7066A (Test leads)
8919 (Ceramic fuse [10A/600V])× 1
8923 (Fuse [0.5A/600V])× 1
R6× 2
Instruction Manual
Optional Accessories7234 (Crocodile clip test lead)
9095 (Carrying case)
Back to top