TOOLTOP ET75 Process Multimeter Signal Source 2 in 1 Ohm Diode Multifuction Process Calibrator Loop Supply Simulate Transmitter

The Process Multimeter is a battery-operated process maintain ace field device which combined both digital-parameter function with process-signal source together.
Functioning as follows:
1. Measurement function of TC voltage, DC voltage , Ohms, DC, Continuity and Diode; Data reserving function;
2. Output function of DC (Constant, Manual-Step and SIMULATE modes)
3. Loop-circuit testing function; Powering the loop circuit with 24 Voltage and testing the current; Built-in 250 Ω HART loop resistance
4.Safety: complied with IEC 61010-1 safety requirements for measurement, control and electronic instruments for lab use.
Weight0.3 kg

Features

70 / 100

1. 100 mV, 30 V DC voltage measurement, 20 mA DC current measurement, and switching value measurement;

2. 100 mV, 30 V DC voltage output, 20 mA DC current output and SIMULATE output;

3. V, mA manual step output,automatic waveform output;

4. Simultaneous display of V, mA and percentage;

5. Loop detection function: It simultaneously provides the 24 V loop power supply and measures the current.

6. The following functions are added to the thermocouple type:

7. Eight scale division (i.e., R, S, B, K, E, J, T and N) thermocouple measurement and output function;

8. Temperature display in Celsius degree and Fahrenheit degree;

9. Automatic and manual cold junction compensation function.

Specification

70 / 100
Measuring detailed accuracy indicator
Measuring partRangeFrequencyAccuracyRemark
DC voltage50V10mV0.5%+4• Measuring impedance 10 MΩ (standard value)
• Common mode restrain: 50Hz or 60Hz > 100Db
• String mode restrain:50Hz or 60Hz > 45dB
• Overload protection: 600V (pea’k –pea’k value)
AC voltage500V100mV0.5%+20  ( 45Hz~100Hz )• Frequency beeps: 45Hz~400Hz
• Adaptive to range from 10% to 100%
• AC conversion: mean value
• Measuring impedence:10 MΩ(standard value)<100pF
• Common mode restrain: 50Hz or 60Hz > 100Db
2%+20  ( 100Hz~400Hz )• Overload protection: 600V(pea’k –pea’k value)
Ohm5kΩ0.001kΩ0.5%+4• open-circuit voltage: <5V;
• short-circuit current: about 0.1mA.
• leads resistance excluded in the accuracy;
• overload protection: 600V
Continuity500Ω0.1ΩShort-circuit beep is about 20Ω• open-circuit voltage: <5V
• short-circuit current: about 0.1mA.
Diode2V0.001V1%+20• overload protection: 600V(pea’k –pea’k value)
DC current20mA0.001mA0.2%+4• overload protection: 100mA/250V fast-melt protection;
• loaded voltage: about 18mV/mA
Outputting detailed accuracy indicator
Output functionRangeOutput designated rangeAccuracyRemark
CDI DC current20mA0.000~22.000mA0.2%+4• Max. load: 1kΩ at 20mA
Simulate transmitter-20mA0.000~-22.000mA• External power supply: 5~28V
• Max. load: 1kΩ at 20mA
Loop-circuit power24V ±10%• Max. output current 25mA
Simulating Transmitter
25%;100%Step output
Display current and % of span
Loop power24V
Loop Detection
The 24V loop power supply and measuring the current
Built in 250 Ω HART loop resistance
General Information
Auto Power-off
SafetyCAT Ⅳ 600V  Pollution Degree 2
Power Supply2×1.5V ;AA  Batteries (Not included)