UT586 Digital RCD (ELCB) Tester

UT580 series digital RCD (ELCB) testers are necessary tools for engineering quality monitoring by measuring RCD (ELCB) trip time and current.
Users can set X1/2, X1, X2, X5 the rated trip current to check RCD (ELCB) response rate under various conditions.

Description

[su_tabs vertical=”yes”][su_tab title=”Basic Features” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Basic Features

1. Lock measurement; automatically begin measurement after powering on
2. Test lead connection check
3. Phase angle selection (0°and 180°), can detect the fastest trigger time
4. AUTO RAMP measurement, trip current and time real-time display
5. MANUAL RAMP measurement (20%~110% step, 5% step length)
6. 1A trigger test
7. Fuse protection; data hold, over range indication, double insulation
[/su_tab]
[su_tab title=”Tech. Spec” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Tech. Spec

[su_table responsive=”yes”]

Specifications

Range

UT586

10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 2000ms
x 1 10mA/20mA/30mA/100mA/200mA/300mA 2000ms
500mA/1000mA 200ms
x 2 10mA/20mA/30mA/100mA/300mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA 200ms
x 5 10mA/20mA/30mA/100mA/200mA 300ms
10mA/20mA/30mA/100mA/200mA 200ms
AUTO RAMP 10mA/20mA/30mA/100mA/300mA/500mA 300ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 300ms
MANUAL RAMP 10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 300ms
Trip current accuracy ±10%
Trip time accuracy ±(0.6%+4)
Trip time resolution 1ms
Operating voltage (frequency): 230V (50Hz) ±10%
AC voltage 60V~400V (Frequency: 50Hz~60Hz) ±(5%+2)

Features

Auto power off
Low battery indication
Data hold
LCD backlight
Contact voltage automatic detection
Over-temperature detection
Lock measurement
Connections check Lamps indication
Fused

General Characterisitics

Power 1.5V battery (R6) x 8
Display 125mm x 37mm
Product color Red and grey
Product net weight 1000g
Product size 210mm x 175mm x 90mm
Standard accessories Batteries, test line, holster, gallus, tool box
Standard individual packing Gift box, English manual
Standard quantity per carton 1pcs
Standard carton measurement 340mm x 140mm x 340mm
Standard carton gross weight 3.4kg

[/su_tab]
[su_tab title=”Models & Comparison” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Models & Comparison

[su_table responsive=”yes”]

Specifications

Range

UT585

UT586

RCD measurement Range setting Rated operating current Trip time
x 1/2 10mA/20mA/30mA/100mA/300mA/500mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 2000ms
x 1 10mA/20mA/30mA/100mA/300mA/500mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA 2000ms
500mA/1000mA 200ms
x 2 10mA/20mA/30mA/100mA/300mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA 200ms
x 5 10mA/20mA/30mA/100mA/200mA 300ms
10mA/20mA/30mA/100mA/200mA 200ms
AUTO RAMP 10mA/20mA/30mA/100mA/300mA/500mA 300ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 300ms
MANUAL RAMP 10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 300ms
Trip current accuracy ±10% ±10%
Trip time accuracy ±(0.6%+4) ±(0.6%+4)
Trip time resolution 1ms 1ms
Operating voltage (frequency): 230V (50Hz) ±10% ±10%
AC voltage 60V~400V (Frequency: 50Hz~60Hz) ±(5%+2) ±(5%+2)
DC voltage ±60V~±400V ±(5%+2)

Features

Auto power off
Low battery indication
Data hold
LCD backlight
Contact voltage automatic detection
Over-temperature detection
Lock measurement
Connections check Lamps indication
Fused

General Characterisitics

Power 1.5V battery (R6) x 8
Display 125mm x 37mm
Product color Red and grey
Product net weight 1000g
Product size 210mm x 175mm x 90mm
Standard accessories Batteries, test line, holster, gallus, tool box
Standard individual packing Gift box, English manual
Standard quantity per carton 1pcs
Standard carton measurement 340mm x 140mm x 340mm
Standard carton gross weight 3.4kg

[/su_table]
[/su_tab]
[/su_tabs]

Reviews

There are no reviews yet.

Be the first to review “UT586 Digital RCD (ELCB) Tester”

Your email address will not be published. Required fields are marked *