• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.

69 / 100

Kyoritsu KEW 2056R AC/DC Digital Clamp Meters

• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.

Features

69 / 100

•  Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• kEW 2056R, True RMS enables an accurate measurement.

 

Specifications

69 / 100
AC A (RMS) 0 – 600.0/1000Amp
±2.0%rdg±5dgt (50/60Hz)
±3.5%rdg±5dgt (40 – 500Hz)
DC A 0 – 600.0/1000A
±1.5%rdg±5dgt
AC V 6/60/600V
Auto Range
±1.5%rdg±4dgt (50/60Hz)
±3.5%rdg±5dgt (40 – 400Hz)
DC V 600m/6/60/600V
Auto Range
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Range)
±1%rdg±5dgt (600 – 6M) / ±5%rdg±8dgt (60M)
Continuity buzzer Buzzer Sounds at 100Ω
Capacitance test 400n/4µ/40µF(Auto Ranging)
Temperature -50ºC – +300ºC (With the use of Temp probe 8216)
Frequency/DUTY 10/100/1k/10kHz (Auto Ranging) / 0.1 – 99.9%
Conductor size Ø40mm
Safety Standard IEC 61010-1 CAT IV 600V,
IEC 61010-031,
IEC 61010-2-032,
IEC 61326
Power source R03 (1.5V) (AAA) × 2
Dimensions 254(L) × 82(W) × 36(D)mm
Weight 310g
Included Accessories 7066A (Test leads)
9094 (Carrying case)
Instruction Manual
Optional Accessories 8216 (Temp probe)
Back to top