CMP-2000 Index: WMXXCMP2000 Digital Clamp-on Multimeter - Variety House

CMP-2000 Index: WMXXCMP2000 Digital Clamp-on Multimeter

Description

4 / 100

Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
The instrument has an electronic overload protection of all functions and ranges.

It provides:

AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
Measurement of INRUSH current in start-up phase of electrical device.
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement.
Temperature measurement (Fahrenheit or Celsius).
Frequency measurement.
Duty cycle measurement.
Diode test.
[su_tabs vertical=”yes”][su_tab title=”Basic Features” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Basic Features

AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.

Measurement of INRUSH current in start-up phase of electrical device.

AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.

Resistance measurement and continuity test:

continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement

Temperature measurement (Fahrenheit or Celsius).

Frequency measurement.

Duty cycle measurement.

Diode test.

Additionally:

safe, insulated measuring clamp,
autoranging,
„DATA HOLD” function, for holding measured values,
backlit LCD,
„DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
„MAX/MIN” function,
over range indication,
„AUTO-OFF” function after 30 min.
Electric security:

measurement category: CAT IV 600 V acc. to EN 61010 – 1,
protection class acc. to EN 60529: IP20,
Other technical data:

power supply, 9 V battery type 6LR61,
display: 6600 counts, backlit LCD,
continuity test: threshold 30 Ω,
diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
low battery indication: BAT displayed,
over range indication: ‘OL’ displayed,
temperature sensor: type K thermocouple,
input impedance: ca.10 MΩ (V DC and V AC),
AC bandwidth: 50…500 Hz,
auto power OFF: 30 minutes,
dimensions: 281 x 108 x 53 mm,
weight: 570 g (with battery),
accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.
Rated operational conditions:

able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
operating temperature: 0…+50 °C,
storage temperature: -20…+60 °C,
operating altitude: max 2000 m.

Specification

4 / 100

 

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 5 digits)
660…2000 A 1 A ±(3,0% m.v. + 5 digits) for 660…1000 A
±(5,0% m.v. + 5 digits) for 1000…2000 A
Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 10 digits) for 50…60 Hz
±(3,0% m.v. + 10 digits) for 61…400 Hz
660…1500 A 1 A ±(2,5% m.v. + 10 digits) for 50…60 Hz
i 660…1000 A
±(3,5% m.v. + 10 digits) for 61…400 Hz
and 660…1000 A
±(5,0% m.v. + 10 digits) for 50…400 Hz
and 1000…1500
Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(0,5% m.v. + 2 digits)
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…1000 V 1 V
Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(1,5% m.v. + 8 digits)
for 50…500 Hz
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…750 V 1
Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 5 digits)
0,660…6,599 kΩ 0,001 kΩ
6,60…65,99 kΩ 0,01 kΩ
66,0…659,9 kΩ 0,1 kΩ
0,660…6,599 MΩ 0,001 MΩ ±(2,0% m.v. + 5 digits)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)
Range Resolution Accuracy
0,0…6,599 nF 0,001 nF ±(3,0% m.v. + 30 digits)
6,60…65,99 nF 0,01 nF ±(3,0% m.v. + 10 digits)
66,0…559,9 nF 0,1 nF ±(3,0% m.v. + 30 digits)
6,600…59,999 µF 0,001 µF ±(3,0% m.v. + 10 digits)
66,00…659,99 µF 0,01 µF
660…659,999 µF 0,100 µF
0,660…6,600 mF 0,001 mF
Range Resolution Accuracy
10…65,99 Hz 0,01 Hz ±(0,1% m.v. + 5 digits)
66,0…659,9 Hz 0,1 Hz
0,660…6,599 kHz 0,001 kHz
6,60…65,99 kHz 0,01 kHz
66,0…659,9 kHz 0,1 kHz
0,660…1,000 MHz 0,001 MHz
Range Resolution Accuracy
-20…0°C 1°C ±(2,0% m.v. + 3°C)
0…399°C ±(1,0% m.v. + 2°C)
400…1000°C ±(2,0% m.v. + 3°C)
-4…31°F 1°F ±(2,0% m.v. + 6°F)
32..749°F ±(1,0% m.v. + 4°F)
750…1832°F ±(2,0% m.v. + 6°F)
ange Resolution Accuracy
5…95% 0,1% ±(2,0% m.v. + 10 digits)
Back to top