Product Details
● Display 4000 counts
● Auto & Manual Ranging
● Relative Measurement
● Diode Open Voltage 1.5V
● Continuity Buzzer less then 50±20Ω
● Data Hold
● Auto Power Off
● Transistor hFE 0~1000
● Low Battery Display
● Display 4000 counts
● Auto & Manual Ranging
● Relative Measurement
● Diode Open Voltage 1.5V
● Continuity Buzzer less then 50±20Ω
● Data Hold
● Auto Power Off
● Transistor hFE 0~1000
● Low Battery Display
1 | Specifications | Range | Resolution | Accuracy |
2 | DC Voltage | 400mV/4V/40V/400V | 0.1mV/1mV/10mV/0.1V | ±(0.7%+2) |
3 | 600V | 0.1V/1V | ±(0.8%+2) | |
4 | AC Voltage | 400 mV | 0.1mV | ±(3.0%+3) |
5 | 4V/40V/400V | 1mV/10mV/0.1V | ±(0.8%+3) | |
6 | 600V | 0.1V/1V | ±(1.2%+3) | |
7 | DC Current | 400μA/4000μA/40mA/400mA | 0.1μA/1μA/10μA/0.1mA | ±(1.2%+3) |
8 | 10Α | 1mA/10mA | ±(2.0%+5) | |
9 | AC Current | 400μA/4000μA/40mA/400mA | 0.1μA/1μA/10μA/0.1mA | ±(1.5%+5) |
10 | 10Α | 1mA/10mA | ±(3.0%+7) | |
11 | Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4ΜΩ | 0.1Ω/1Ω/10Ω/0.1kΩ/1kΩ | ±(1.2%+2) |
12 | 40ΜΩ | 0.01MΩ | ±(2.0%+5) | |
13 | Capacitance | 4nF | 1pF | ±(4.0%+25) |
14 | 40nF/400nF/4μF/40μF/200μF | 0.01nF/0.1nF/1nF/10nF/0.1μF | ±(4.0%+15) | |
15 | Frequency | 10Hz/100Hz/1kHz | 0.01Hz/0.01Hz/0.1Hz | ±(2.0%+5) |
16 | 10kHz/100kHz/200kHz | 1Hz/10Hz/0.1kHz | ±(2.0%+5) | |
17 | >200kHz | 0.1kHz | Reference | |
18 | DC Current (for Clamp Meter) | 40A | 1A/1mV | ±(0.8%+3) |
19 | 400A | 1A/1mV | ±(0.8%+3) | |
20 | AC Current (for Clamp Meter) | 40A | 1A/1mV | ±(1.0%+3) |
21 | 400A | 1A/1mV | ±(1.0%+3) | |
22 | Duty Cycle | 5% ~ 95% | 0.1% | ±(2.0%+2) |