Basic Features

  • ■3-3 / 4 digits 4000 count
  • ■ 0.5% best accuracy
  • ■ Capacitance measurement
  • ※Not suitable for measurement of condensers with large leak current.
  • ■ Data hold / Range hold
  • ■ Safety cover for the 4・10A terminal
  • ■ Safety cap for AC adapter terminal
  • ■ Protective holster with wall hanger and lead holder
  • ■ Tilt stand
  • ■ Optical link RS232C / USB interface (optional)

Sampling rate : 3 times / sec.

Optional Accessories

Software : PC Link 7
Optical PC link cable : KB-USB20
Clamp probe : CL-22AD, CL33DC, CL3000
Temperature probe : T-300PC (PC Link software is necessary.)
AC adapter : AD-71AC-2 (100V), AD-72AC (220V)
Test lead : TL-21M, TLF-120
Carrying case : C-PC10/S, C-SP
Adapter : CL-13a, CL-14,CL-15a, CL-DG3a, TL-9IC, TL-A4, TL-A7M, TL-A7M2

Safety/Specifications

PC20 Measuring range Best Accuracy Resolution
DCV 400m/4/40/400m/1000V +(0.5%+2) 0.1mV
ACV 4/40/400/750V +(1.2%+5) 0.001V
DCA 400u/4000u/40m/400m/4/10A +(1.5%+2) 0.1uA
ACA 400u/4000u/40m/400m/4A/10A +(1.8%+5) 0.1uA
Resistance 400/4k/40/400k/4M/40M +(1.2%+4) 0.1
Capacitance 50n/500n/5u/50u/100uF +5%+6) 0.01nF
Continuity Buzzer sounds at between 10 and 120 .Open voltage:approx.0.4V
Diode test Open voltage:approx.1.5V
Bandwidth 40Hz-500khz(below500V) 40Hz-1kHz(ACA)
Fuse/Battery 0.5A/250V IR1500A/5X20mm 12.5A/250V IR125A/6.3X32mm R6X2
Size/Mass H167XW90XD48mm/330g (including holster)
Standard accessones included Test lead(TL-21a) Holster (H-70),Instruction manual