PC20 Digital Multimeters?Data processing (PC Link) - Variety House

Basic Features

  • ■3-3 / 4 digits 4000 count
  • ■ 0.5% best accuracy
  • ■ Capacitance measurement
  • ※Not suitable for measurement of condensers with large leak current.
  • ■ Data hold / Range hold
  • ■ Safety cover for the 4・10A terminal
  • ■ Safety cap for AC adapter terminal
  • ■ Protective holster with wall hanger and lead holder
  • ■ Tilt stand
  • ■ Optical link RS232C / USB interface (optional)

Sampling rate : 3 times / sec.

Optional Accessories

Software : PC Link 7
Optical PC link cable : KB-USB20
Clamp probe : CL-22AD, CL33DC, CL3000
Temperature probe : T-300PC (PC Link software is necessary.)
AC adapter : AD-71AC-2 (100V), AD-72AC (220V)
Test lead : TL-21M, TLF-120
Carrying case : C-PC10/S, C-SP
Adapter : CL-13a, CL-14,CL-15a, CL-DG3a, TL-9IC, TL-A4, TL-A7M, TL-A7M2

Safety/Specifications

PC20Measuring rangeBest AccuracyResolution
DCV400m/4/40/400m/1000V+(0.5%+2)0.1mV
ACV4/40/400/750V+(1.2%+5)0.001V
DCA400u/4000u/40m/400m/4/10A+(1.5%+2)0.1uA
ACA400u/4000u/40m/400m/4A/10A+(1.8%+5)0.1uA
Resistance400/4k/40/400k/4M/40M+(1.2%+4)0.1
Capacitance50n/500n/5u/50u/100uF+5%+6)0.01nF
ContinuityBuzzer sounds at between 10 and 120 .Open voltage:approx.0.4V
Diode testOpen voltage:approx.1.5V
Bandwidth40Hz-500khz(below500V) 40Hz-1kHz(ACA)
Fuse/Battery0.5A/250V IR1500A/5X20mm 12.5A/250V IR125A/6.3X32mmR6X2
Size/MassH167XW90XD48mm/330g (including holster)
Standard accessones includedTest lead(TL-21a) Holster (H-70),Instruction manual
Back to top