UT585 Digital RCD (ELCB) Tester - Variety House

UT585 Digital RCD (ELCB) Tester

UT580 series digital RCD (ELCB) testers are necessary tools for engineering quality monitoring by measuring RCD (ELCB) trip time and current.
Users can set X1/2, X1, X2, X5 the rated trip current to check RCD (ELCB) response rate under various conditions.

[su_tabs vertical=”yes”][su_tab title=”Basic Features” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Basic Features

1. Lock measurement; automatically begin measurement after powering on
2. Test lead connection check
3. Phase angle selection (0°and 180°), can detect the fastest trigger time
4. AUTO RAMP measurement, trip current and time real-time display
5. 1A trigger test
6. Fuse protection; data hold, over range indication, double insulation
[/su_tab]
[su_tab title=”Tech. Spec” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Tech. Spec

[su_table responsive=”yes”]

Specifications

Range

UT585

RCD measurement Range setting Rated operating current Trip time
x 1/2 10mA/20mA/30mA/100mA/300mA/500mA 1000ms
x 1 10mA/20mA/30mA/100mA/300mA/500mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA 2000ms
500mA/1000mA 200ms
x 2 10mA/20mA/30mA/100mA/300mA 1000ms
x 5 10mA/20mA/30mA/100mA/200mA 300ms
10mA/20mA/30mA/100mA/200mA 200ms
AUTO RAMP 10mA/20mA/30mA/100mA/300mA/500mA 300ms
Trip current accuracy ±10%
Trip time accuracy ±(0.6%+4)
Trip time resolution 1ms
Operating voltage (frequency): 230V (50Hz) ±10%
AC voltage 60V~400V (Frequency: 50Hz~60Hz) ±(5%+2)
DC voltage ±60V~±400V ±(5%+2)

Features

Auto power off
Low battery indication
Data hold
LCD backlight
Contact voltage automatic detection
Over-temperature detection
Lock measurement
Connections check Lamps indication
Fused

General Characterisitics

Power 1.5V battery (R6) x 8
Display 125mm x 37mm
Product color Red and grey
Product net weight 1000g
Product size 210mm x 175mm x 90mm
Standard accessories Batteries, test line, holster, gallus, tool box
Standard individual packing Gift box, English manual
Standard quantity per carton 1pcs
Standard carton measurement 340mm x 140mm x 340mm
Standard carton gross weight 3.4kg

[/su_tab]
[su_tab title=”Models & Comparison” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Models & Comparison

[su_table responsive=”yes”]

Specifications

Range

UT585

UT586

RCD measurement Range setting Rated operating current Trip time
x 1/2 10mA/20mA/30mA/100mA/300mA/500mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 2000ms
x 1 10mA/20mA/30mA/100mA/300mA/500mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA 2000ms
500mA/1000mA 200ms
x 2 10mA/20mA/30mA/100mA/300mA 1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA 200ms
x 5 10mA/20mA/30mA/100mA/200mA 300ms
10mA/20mA/30mA/100mA/200mA 200ms
AUTO RAMP 10mA/20mA/30mA/100mA/300mA/500mA 300ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 300ms
MANUAL RAMP 10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA 300ms
Trip current accuracy ±10% ±10%
Trip time accuracy ±(0.6%+4) ±(0.6%+4)
Trip time resolution 1ms 1ms
Operating voltage (frequency): 230V (50Hz) ±10% ±10%
AC voltage 60V~400V (Frequency: 50Hz~60Hz) ±(5%+2) ±(5%+2)
DC voltage ±60V~±400V ±(5%+2)

Features

Auto power off
Low battery indication
Data hold
LCD backlight
Contact voltage automatic detection
Over-temperature detection
Lock measurement
Connections check Lamps indication
Fused

General Characterisitics

Power 1.5V battery (R6) x 8
Display 125mm x 37mm
Product color Red and grey
Product net weight 1000g
Product size 210mm x 175mm x 90mm
Standard accessories Batteries, test line, holster, gallus, tool box
Standard individual packing Gift box, English manual
Standard quantity per carton 1pcs
Standard carton measurement 340mm x 140mm x 340mm
Standard carton gross weight 3.4kg

[/su_table]
[/su_tab]
[/su_tabs]

Back to top