Fluke 376 FC True-RMS Clamp Meter - Variety House

Fluke 376 FC True-RMS Clamp Meter

Key features

Connect your meter to your smartphone with Fluke Connect Measurements
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
Record results directly to your phone and the Cloud
Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
TPAK magnetic hanging strap (included)
Integrated VFD low pass filter for accurate motor drive measurements
Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
CAT IV 600 V, CAT III 1000 V safety rating
Three-year warranty
Soft carrying case
Measurement Capability

1000 A ac and dc current measurement
2500 A ac current measurement with iFlex flexible current probe
1000 V ac and dc voltage measurement
True-rms voltage and current for accurate measurements on non-linear signals
Frequency measurement to 500 Hz with body jaw and iFlex
Resistance measurement to 60 kΩ with continuity detection
Min, max, average, and inrush recording to capture variations automatically
500 mV dc measurement range to interface with other accessories
1000 μF capacitance measurement

Description

9 / 100

Fluke 376 FC True-RMS Clamp Meter

The Fluke 376 FC is part of the Fluke Connect family of wireless test tools. Now you can:

Log and trend measurements to pinpoint intermittent faults
Transmit results wirelessly via Fluke Connect® Measurements app
Create and send reports right from the field
Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.

Specifications

9 / 100

 Fluke 376 FC True-RMS Clamp Meter

General Specifications
AC Current via Jaw
Range999.9 A
Resolution0.1 A
Accuracy2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range2500 A
Resolution0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
i2500-10 Flexi2500-18 Flex
A
Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)
Error±0.5 %±0.5 %
B
Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)
Error±1.0 %±1.0 %
C
Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)
Error±2.0 %±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range600.0 A
Resolution0.1 A
Accuracy2% ±5 digits
AC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1% ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1% ±5 digits
Frequency via Jaw
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5% ±5 digits
Trigger level5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5% ±5 digits
Trigger level5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range60 kΩ
Resolution0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy1% ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground1000 V
Batteries2 AA, NEDA 15A, IEC LR6
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity –
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Size (L x W x H)249 x 85 x 45 mm
Weight395 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
IP ratingIEC 60529: IP30, non-operating
Radio Frequency Certification FCC IDT68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C