Description
DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:
continuity test with acoustic signalling (beeper) for resistance below 50.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.
Additionally:
safe, insulated measuring clamps,
double molded housing,
autoranging/manual range selection,
DATA HOLD function, for holding measured values,
backlit LCD,
REL function,
over range indication,
AUTO-OFF function.
Basic Features
DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.
Resistance measurement and continuity test:
continuity test with acoustic signalling (beeper) for resistance below 50 Ω.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement
Diode test.
Additionally:
safe, insulated measuring clamps,
double molded housing,
autoranging/manual range selection,
„DATA HOLD” function, for holding measured values,
backlit LCD,
„REL” function,
over range indication,
„AUTO-OFF” function.
Electric security:
measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
protection class acc. to EN 60529: IP40
Other technical data:
power supply: 9 V battery type 6LR61
display: 4000 counts, backlit LCD
continuity test: I<0,5 mA, sound signal for R<50 Ω
diode test: I = 0,3 mA, U0 = 1,5 V DC
over range indication: 0L displayed
sampling rate: 2 times per second
input impedance: 10 MΩ (V DC and V AC)
clamp size: opening 30 mm (1,2”)
auto power OFF: approx. 30 min.
dimensions: 197 x 70 x 40 mm
weight: 183 g
accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
quality standard: ISO 9001
Rated operational conditions:
operating temperature: 0…+40°C
storage temperature: -20…+60°C
operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
operating altitude: max 2000 m
Temperature measurement*probe (K type) accuracy not included
Frequency measurement
- csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)
AC current measurement
- frequency range: 50…60 Hz.
DC current measurement
AC voltage measurement
- frequency range: 50…400 Hz.
DC voltage measurement
Resistance measurement
Capacitance measurement