UT586 Digital RCD (ELCB) Tester - Variety House

UT586 Digital RCD (ELCB) Tester

UT580 series digital RCD (ELCB) testers are necessary tools for engineering quality monitoring by measuring RCD (ELCB) trip time and current.
Users can set X1/2, X1, X2, X5 the rated trip current to check RCD (ELCB) response rate under various conditions.

[su_tabs vertical=”yes”][su_tab title=”Basic Features” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Basic Features

1. Lock measurement; automatically begin measurement after powering on
2. Test lead connection check
3. Phase angle selection (0°and 180°), can detect the fastest trigger time
4. AUTO RAMP measurement, trip current and time real-time display
5. MANUAL RAMP measurement (20%~110% step, 5% step length)
6. 1A trigger test
7. Fuse protection; data hold, over range indication, double insulation
[/su_tab]
[su_tab title=”Tech. Spec” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Tech. Spec

[su_table responsive=”yes”]

Specifications

Range

UT586

10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA2000ms
x 110mA/20mA/30mA/100mA/200mA/300mA2000ms
500mA/1000mA200ms
x 210mA/20mA/30mA/100mA/300mA1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA200ms
x 510mA/20mA/30mA/100mA/200mA300ms
10mA/20mA/30mA/100mA/200mA200ms
AUTO RAMP10mA/20mA/30mA/100mA/300mA/500mA300ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA300ms
MANUAL RAMP10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA300ms
Trip current accuracy±10%
Trip time accuracy±(0.6%+4)
Trip time resolution1ms
Operating voltage (frequency): 230V (50Hz)±10%
AC voltage60V~400V (Frequency: 50Hz~60Hz)±(5%+2)

Features

Auto power off
Low battery indication
Data hold
LCD backlight
Contact voltage automatic detection
Over-temperature detection
Lock measurement
Connections checkLamps indication
Fused

General Characterisitics

Power1.5V battery (R6) x 8
Display125mm x 37mm
Product colorRed and grey
Product net weight1000g
Product size210mm x 175mm x 90mm
Standard accessoriesBatteries, test line, holster, gallus, tool box
Standard individual packingGift box, English manual
Standard quantity per carton1pcs
Standard carton measurement340mm x 140mm x 340mm
Standard carton gross weight3.4kg

[/su_tab]
[su_tab title=”Models & Comparison” disabled=”no” anchor=”” url=”” target=”blank” class=””]

Models & Comparison

[su_table responsive=”yes”]

Specifications

Range

UT585

UT586

RCD measurementRange settingRated operating currentTrip time
x 1/210mA/20mA/30mA/100mA/300mA/500mA1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA2000ms
x 110mA/20mA/30mA/100mA/300mA/500mA1000ms
10mA/20mA/30mA/100mA/200mA/300mA2000ms
500mA/1000mA200ms
x 210mA/20mA/30mA/100mA/300mA1000ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA200ms
x 510mA/20mA/30mA/100mA/200mA300ms
10mA/20mA/30mA/100mA/200mA200ms
AUTO RAMP10mA/20mA/30mA/100mA/300mA/500mA300ms
10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA300ms
MANUAL RAMP10mA/20mA/30mA/100mA/200mA/300mA/500mA/1000mA300ms
Trip current accuracy±10%±10%
Trip time accuracy±(0.6%+4)±(0.6%+4)
Trip time resolution1ms1ms
Operating voltage (frequency): 230V (50Hz)±10%±10%
AC voltage60V~400V (Frequency: 50Hz~60Hz)±(5%+2)±(5%+2)
DC voltage±60V~±400V±(5%+2)

Features

Auto power off
Low battery indication
Data hold
LCD backlight
Contact voltage automatic detection
Over-temperature detection
Lock measurement
Connections checkLamps indication
Fused

General Characterisitics

Power1.5V battery (R6) x 8
Display125mm x 37mm
Product colorRed and grey
Product net weight1000g
Product size210mm x 175mm x 90mm
Standard accessoriesBatteries, test line, holster, gallus, tool box
Standard individual packingGift box, English manual
Standard quantity per carton1pcs
Standard carton measurement340mm x 140mm x 340mm
Standard carton gross weight3.4kg

[/su_table]
[/su_tab]
[/su_tabs]

Back to top